The Default Application 15-4
590 Series DC Digital Converter
Programming Block Diagram - Sheet 2
AUX PORT P2
ENABLED [147] SRL LINK ENABLE
0
[140] GROUP ID (GID)
0
[141] UNIT ID (UID)
EI ASCII
[149] PROTOCOL
9600
[151] BAUD RATE
DISABLED
[153] ESP SUP. (ASCII)
0.00%
[145] CHANGEBAND (BIN)
0x00C0
[150] ERROR REPORT
0xFFFF
[148] PNO. 7
DIAMETER CALC.
DIAMETER [427]
0.00%
MOD OF LINE SPEED [428]
0.00%
MOD OF REEL SPEED [429]
0.00%
UNFILTERED DIAMETER [430]
0.00%
0.00 %
[424] LINE SPEED
0.00 %
[437] REEL SPEED
10.00 %
[425] MIN DIAMETER
5.00 %
[426] MIN SPEED
10.00 %
[462] RESET VALUE
DISABLED
[463] EXTERNAL RESET
5.0 SECS
[453] RAMP RATE
LINK 11
OUTPUT [391]
0
0
[390] INPUT
0
[394] AUX INPUT
OFF
[392] ADVANCED
SWITCH
[393] MODE
LINK 12
OUTPUT [396]
0
0
[395] INPUT
0
[399] AUX INPUT
OFF
[397] ADVANCED
SWITCH
[398] MODE
miniLINK
0.00 %
[339] VALUE 1
0.00 %
[340] VALUE 2
0.00 %
[341] VALUE 3
0.00 %
[342] VALUE 4
0.00 %
[343] VALUE 5
0.00 %
[344] VALUE 6
0.00 %
[345] VALUE 7
0.00 %
[379] VALUE 8
0.00 %
[380] VALUE 9
0.00 %
[381] VALUE 10
0.00 %
[382] VALUE 11
0.00 %
[383] VALUE 12
0.00 %
[384] VALUE 13
0.00 %
[385] VALUE 14
OFF
[346] LOGIC 1
OFF
[347] LOGIC 2
OFF
[348] LOGIC 3
OFF
[349] LOGIC 4
OFF
[350] LOGIC 5
OFF
[351] LOGIC 6
OFF
[352] LOGIC 7
OFF
[353] LOGIC 8
PID
PID OUTPUT [417]
0.00%
PID CLAMPED [416]
FALSE
PID ERROR [415]
0.00%
1.0
[404] PROP. GAIN
5.00 SECS
[402] INT. TIME CONST.
0.000 SECS
[401] DERIVATIVE TC
100.00%
[405] POSITIVE LIMIT
-100.00%
[406] NEGATIVE LIMIT
0.2000
[407] O/P SCALER (TRIM)
0.00%
[410] INPUT 1
0.00%
[411] INPUT 2
1.0000
[412] RATIO 1
1.0000
[413] RATIO 2
1.0000
[418] DIVIDER 1
1.0000
[414] DIVIDER 2
ENABLED
[408] ENABLE
OFF
[409] INT. DEFEAT
0.100 SECS
[403] FILTER T.C.
0
[473] MODE
20.00%
[474] MIN PROFILE GAIN
PROFILED GAIN [475]
0.0
TAPER CALC.
TAPERED DEMAND [452]
0.00%
TOT. TENS DEMAND [441]
0.00%
0.00 %
[438] TAPER
0.00 %
[439] TENSION SPT.
0.00 %
[440] TENSION TRIM
SETPOINT SUM 2
SPT. SUM 2 [451]
0.00%
0.00 %
[444] INPUT 0
1.0000
[447] RATIO 0
1.0000
[448] DIVIDER 0
0.00 %
[443] INPUT 1
1.0000
[446] RATIO 1
1.0000
[466] DIVIDER 1
0.00 %
[445] INPUT 2
100.00 %
[449] LIMIT
OUTPUT 0 [491]
OUTPUT 1 [492]
TENSION & COMP
TENS+COMP [478]
INERTIA COMP [485]
0.00%
0.00 %
[487] STATIC COMP
0.00 %
[488] DYNAMIC COMP
ENABLED
[489] REWIND
0.00 %
[479] FIX. INERTIA COMP
0.00 %
[480] VAR. INERTIA COMP
100.00 %
[479] ROLL WIDTH/MASS
0.00 %
[498] LINE SPEED SPT
10
[482] FILTER T.C.
10
[483] RATE CAL
0.00 %
[484] NORMALISED dv/dt
1.0000
[486] TENSION SCALER
TORQUE CALC.
POS. I CLAMP [435]
0
NEG. I CLAMP [436]
0
0.00 %
[432] TORQUE DEMAND
ENABLED
[433] TENSION ENABLE
ENABLED
[434] OVER WIND
USER FILTER
OUTPUT [296]
0.00
0.00
[295] INPUT
0 PNO 112
0 PNO 113
0 PNO 114
0 PNO 115
0 PNO 116
0 PNO 117
0 PNO 118
0 PNO 119
379 PNO 120
380 PNO 121
381 PNO 122
382 PNO 123
383 PNO 124
384 PNO 125
385 PNO 126
0 PNO 127

Table of Contents