6-8 Programming Your Application
590 Series DC Digital Converter
AUX I/O
The auxiliary I/O parameters are primarily
intended to extend the functionality of the
serial links by allowing them access to the
drive analog and digital terminals.
AUX I/O
START (C3) [ 68]
–
OFF
JOG INPUT (C4) [ 69]
–
OFF
ENABLE (C5) [ 70]
–
OFF
ON
–
[161] AUX START
–
ON
–
[227] AUX JOG
–
ON
–
[168] AUX ENABLE
–
OFF
–
[ 94] AUX DIGOUT 1
–
OFF
–
[ 95] AUX DIGOUT 2
–
OFF
–
[ 96] AUX DIGOUT 3
–
0.00 %
–
[128] ANOUT 1
–
0.00 %
–
[129] ANOUT 2
–
OFF
–
[496] JOG/SLACK
–
OFF
–
[497] ENABLE
–
MMI Menu Map
1
SETUP PARAMETERS
2
AUX I/O
AUX START
AUX JOG
AUX ENABLE
AUX DIGOUT 1
AUX DIGOUT 2
AUX DIGOUT 3
ANOUT 1
ANOUT 2
JOG/SLACK
ENABLE
Parameter Descriptions
AUX START
Range: ON/OFF
Software Start/Run command.
AUX JOG
Range: ON/OFF
Software Jog command.
AUX ENABLE
Range: ON/OFF
Software Enable command.
AUX DIGOUT 1
Range: ON/OFF
Software digital output 1.
AUX DIGOUT 2
Range: ON/OFF
Software digital output 2.
AUX DIGOUT 3
Range: ON/OFF
Software digital output 3.
ANOUT 1
Range: -100.00 to 100.00 %
Software analog output 1.
ANOUT 2
Range: -100.00 to 100.00 %
Software analog output 2.
JOG/SLACK
Reserved parameter for use by Parker SSD Drives.
ENABLE
Reserved parameter for use by Parker SSD Drives.
START (C3)
Refer to the DIAGNOSTICS function block description, page 6-
18.
JOG INPUT (C4)
(DIGITAL INPUT C4)
Refer to the DIAGNOSTICS function block description, page 6-
18.
ENABLE (C5)
(DIGITAL INPUT C5)
Refer to the DIAGNOSTICS function block description, page 6-
18.