6-34 Programming Your Application
590 Series DC Digital Converter
LINK 11 & LINK 12
Links 11 and 12 allow further functionality within the block diagram. The following diagram
shows the internal schematic for an advanced link.
LINK 11
OUTPUT [391]
0
0
[390] INPUT
0
[394] AUX INPUT
OFF
[392] ADVANCED
SWITCH
[393] MODE
LINK 12
OUTPUT [396]
0
0
[395] INPUT
0
[399] AUX INPUT
OFF
[397] ADVANCED
SWITCH
[398] MODE
MMI Menu Map
1
SYSTEM
2
CONFIGURE I/O
3
INTERNAL LINKS
4
LINK 11
4
LINK 12
SOURCE TAG
DESTINATION TAG
ADVANCED
MODE
AUX. SOURCE
Parameter Descriptions
INPUT
Range: 0 to 499
(SOURCE TAG)
AUX INPUT
Range: 0 to 499
(AUX. SOURCE)
Provides the second input for the two-input functions of the MODE selection.
ADVANCED
Range: OFF/ON
When OFF it makes the extended link appear as a standard link, i.e. it copies INPUT to
OUTPUT. When ON it extends the link's functionality according to the MODE selected (see
below).
MODE
Range: See below
This determines which operation is performed on the INPUT (and sometimes also the AUX
INPUT) before copying the result into the OUTPUT. It can be combined with ADVANCED to
dynamically switch the OUTPUT between two inputs (INPUT and AUX INPUT). The
functionality of the various MODE selections are shown in the table.
COMPARATOR
MODULUS
SIGN CHANGER
OR
AND
INVERTER
SWITCH
OUTPUT
Range: 0 to 499
(DESTINATION TAG)