Programming Your Application 6-35
590 Series DC Digital Converter
Functional Description
Link 11 & Link 12
-1
x
|x|
Aux Source
Mode
Source
Advanced
Dest
Switch
Inverter
AND
OR
Sign Chg
Modulus
Comparator
Mode Description
SWITCH If ADVANCED = OFF DESTINATION = SOURCE
If ADVANCED = ON DESTINATION = AUX SOURCE
INVERTER If ADVANCED = OFF DESTINATION = SOURCE
If ADVANCED = ON DESTINATION = Logic Inversion of SOURCE
AND If ADVANCED = OFF DESTINATION = SOURCE
If ADVANCED = ON DESTINATION = SOURCE AND AUX SOURCE
OR If ADVANCED = OFF DESTINATION = SOURCE
If ADVANCED = ON DESTINATION = SOURCE OR AUX SOURCE
SIGN CHANGER If ADVANCED = OFF DESTINATION = SOURCE
If ADVANCED = ON DESTINATION = Value sign change of SOURCE
MODULUS If ADVANCED = OFF DESTINATION = SOURCE
If ADVANCED = ON DESTINATION = Modulus of SOURCE
COMPARATOR If ADVANCED = OFF DESTINATION = SOURCE
If ADVANCED = ON If SOURCE < AUX SOURCE DESTINATION = 0
If SOURCE > AUX SOURCE DESTINATION = 1