Programming Your Application 6-3
590 Series DC Digital Converter
Hexadecimal Representation of Trips
The HEALTH WORD and HEALTH STORE parameters use a four digit hexadecimal number
to identify individual trips. Each trip has a unique corresponding number as shown below.
Trip Trip Code
Digit 4 Digit 3 Digit 2 Digit 1
0 OVERSPEED 1
1 MISSING PULSE 2
2 FIELD OVER I 4
3 HEATSINK TRIP 8
4 THERMISTOR 1
5 OVERVOLTS (VA) 2
6 SPEED FEEDBACK 4
7 ENCODER FAILED 8
8 FIELD FAILED 1
9 3 PHASE FAILED 2
10 PHASE LOCK 4
11 5703 RCV ERROR 8
12 STALL TRIP 1
13 OVER I TRIP 2
14 Not used 4
15 ACCTS FAILED 8
When more than one trip is to be represented at the
same time then the trip codes are simply added together
to form the value displayed. Within each digit, values
between 10 and 15 are displayed as letters A to F
For example, if the HEALTH WORD parameter is
01A8 then this represents a “1” in digit 3, an “8” and a
“2” in digit 2, (8+2 = 10, displayed as A) and an 8 in digit 1. This in turn represents the active
trips FIELD FAILED, ENCODER FAILED, OVERVOLTS (VA) and HEATSINK TRIP (an
unlikely situation).
Decimal number Display
10 A
11 B
12 C
13 D
14 E
15 F