6-52 Programming Your Application
590 Series DC Digital Converter
RATIO 2 (A3)
Range: -3.0000 to 3.0000
Speed Setpoint 2 Ratio.
SETPOINT 2 (A3)
Range: -100.00 to 100.00 %
Speed Setpoint 2 - Fixed (non-configurable) setpoint scanned synchronously with the current
loop
SETPOINT 3
Range: -100.00 to 100.00 %
Speed Setpoint 3 (Default Ramp O/P).
SETPOINT 4
Range: -100.00 to 100.00 %
Speed Setpoint 4 (Default 5703 I/P).
MAX DEMAND
Range: 0.00 to 105.00 %
Sets the maximum input to the speed loop. It is clamped at 105% to allow for overshoot in the
external loops.
MIN DEMAND
Range: -105.00 to 0.00%
Sets the minimum input to the speed loop.
OUTPUT
Reserved parameter for use by Parker SSD Drives.
SPEED FEEDBACK
Refer to the DIAGNOSTICS function block description, page 6-
18.
SPEED SETPOINT
Refer to the DIAGNOSTICS function block description, page 6-
18.
SPEED ERROR
Refer to the DIAGNOSTICS function block description, page 6-
18.