COMMUNICATIONS
50 ACR7000 Controller Installation Guide
9 Click the radio button next to Use the following IP address
10 Enter an IP address with the same first three octets as the default ACR7000 IP address (192.168.100).
The last octet of the ACR7000 is by default “1”. Select a different number for the PC in the valid range is
1 to 254. Using 000 or 255 is not valid. In the example the IP address is set to 192.168.100.222. Set the
Subnet mask value to 255.255.255.0. Your window should look like the following:
Figure 7. - Internet Protocol Properties Screen Completed
11 Click OK. It is now safe to close these windows.
IMPORTANT: It is good practice to isolate the ACR7000 and related devices on their
own subnet so that their performance is not affected by high volume
network traffic.
Verifying the IP Address
The following verifies the Ethernet is set up correctly.
1 In Parker Motion Manager, the IP Address box is the value for the controller.
2 In the dialog box, click Connect.
3 In the Terminal Emulator, type VER. If the Ethernet is set up correctly, the terminal emulator reports the
firmware version information for the ACR7000 Controller.