advance degrees indicated by the stroboscopic
lamp.
- Check that the advance degrees match the rev-
olution speed as indicated in the tables.
- In case of abnormal values, check the Pick-Up
and the control unit supplies (positive-negative);
replace the control unit, if required.
- A new control unit prevents the engine from ro-
tating at over 2,000 rpm.
- The programmed control unit allows the engine
revolution within the prescribed limits.
Specific tooling
020330Y Stroboscopic light to check timing
Characteristic
250 spark advance check
10° ± 1° at 2000 Rpm
32° ± 1° at 6000 Rpm
Spark advance variation
Characteristic
Operation threshold
First threshold : 9600±50
Second threshold : 9800±50
Reactivation threshold
First threshold : 9500±50
Second threshold : 9700±50
Spark elimination
First threshold : 1 spark on 7
Second threshold : 2 sparks on 3
Maintenance MSS X9 Evolution 250