Users Manual of MGSW-28240F
39
Insert the wires into the faulty alarm contacts
1. The wire gauge for the terminal block should be in the range of 12 ~ 24 AWG.
2. When performing any of the procedures like inserting the wires or tighten the wire-clamp screws, make
sure the power is OFF to prevent from getting an electric shock.
2.1.6 Wiring the Digital Input / Output
The 6-contact terminal block connector on the front panel of MGSW-28240F is used for Digital Input and Digital Output. Please
follow the steps below to insert wire.
1. The MGSW-28240F offers two DI and DO groups. 1 and 2 are DI groups, 3 and 4 are DO groups and 5 and 6 are GND
(ground).
Figure 2-5 Wiring the Redundant Power Inputs
DI DO GND