EasyManua.ls Logo

Planet MGSW-28240F - DIDO DO Enable; DIDO DO Port Alarm

Planet MGSW-28240F
643 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Users Manual of MGSW-28240F
601
enable : Enable digital input0/1 function
disable : Disable digital input0/1 function
(default: Set or show digital input/output/fault alarm 0/1 status)
DIDO DO Enable
Description:
Set or show the system digital output0/1.
Syntax:
DIDO Do_en [first|second] [enable|disable] [hightolow|lowtohigh]
Parameters:
first : Digital Input/Output 0
second : Digital Input/Output 1
(default: Set or show digital input/output first(0)/second(1) select)
enable : Enable digital input0/1 function
disable : Disable digital input0/1 function
(default: Set or show digital input/output/fault alarm 0/1 status)
hightolow : Trigger -> high to low
lowtohigh : Trigger -> low to high
(default: Set or show digital input/output 0/1 trigger)
DIDO DO Port Alarm
Description:
Set or show the system digital output0/1 port alarm.
Syntax:
DIDO Do_port_alr [first|second] [<port_list>]
Parameters:
first : Digital Input/Output 0
second : Digital Input/Output 1
(default: Set or show digital input/output first(0)/second(1) select)
<port_list>: Port list or 'all', default: All ports