EasyManua.ls Logo

Planet MGSW-28240F - DIDO DI Enable; DIDO DO Act

Planet MGSW-28240F
643 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Users Manual of MGSW-28240F
600
DIDO DI Enable
Description:
Set or show the system digital input0/1.
Syntax:
DIDO Di_en [first|second] [enable|disable] [hightolow|lowtohigh]
Parameters:
first : Digital Input/Output 0
second : Digital Input/Output 1
(default: Set or show digital input/output first(0)/second(1) select)
enable : Enable digital input0/1 function
disable : Disable digital input0/1 function
(default: Set or show digital input/output/fault alarm 0/1 status)
hightolow : Trigger -> high to low
lowtohigh : Trigger -> low to high
(default: Set or show digital input/output 0/1 trigger)
DIDO DO Act
Description:
Set or show the system digital output0/1 action.
Syntax:
DIDO Do_act [first|second] [port|power] [enable|disable]
Parameters:
first : Digital Input/Output 0
second : Digital Input/Output 1
(default: Set or show digital input/output first(0)/second(1) select)
port : port fail
power : power fail
DI1 : DI1 trigger
DI2 : DI2 trigger
(default: Set or show digital output/fault alarm 0/1 action)