603
DIDO Fault Enable
Description:
Set or show the system fault alarm.
Syntax:
DIDO Fault_en [enable|disable]
Parameters:
enable : Enable digital input0/1 function
disable : Disable digital input0/1 function
(default: Set or show digital input/output/fault alarm 0/1 status)
DIDO Fault Port Alarm
Description:
Set or show the system fault alarm of port alarm.
Syntax:
DIDO Fault_port_alr [<port_list>]
Parameters:
<port_list>: Port list or 'all', default: All ports
DIDO Fault Power Alarm
Description:
Set or show the system fault alarm of power alarm.
Syntax:
DIDO Fault_pwr_alr [dc1|dc2] [enable|disable]
Parameters:
dc1 : DC power 1
dc2 : DC power 2
(default: Set or show digital output/fault alarm 0/1 power_fail)
enable : Enable digital input0/1 function
disable : Disable digital input0/1 function