EasyManua.ls Logo

Planet MGSW-28240F - ERPS Command; Erps Add; Erps Mep

Planet MGSW-28240F
643 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Users Manual of MGSW-28240F
613
6.27 ERPS Command
erps add
Description:
Create a new ethernet ring protection group.
<group-id> : protection group id.
<east_port> : protection group Port 0.
<west_port> : protection group Port 1, Port 1 can be 0 for sub-rings.
[major|sub] : ring type i.e major-ring or sub-ring.
[interconnected] : interconnection node or not.
[[virtual_channel] : Virtual channel present or not.
[<major-ring-id>] : major ring group Id for interconnected sub-ring.
Syntax:
Erps add <group-id> <east_port> <west_port> [major|sub] [interconnected] [virtual_channel] [<major-ring-id>]
Parameters:
<group-id> : protection group id 1 64.
<east_port> : Port 0 of a protection group.
<west_port> : Port 1 of a protection group.
major|sub : ring type.
interconnected : Set for interconnected node.
virtual_channel: Set for virtual channel.
<major-ring-id>: major ring of a sub-ring, when configuring as an interconnected node.
Example:
MGSW
-28240F:/>erps add 1 1 2 major
erps mep
Description:
Associating Port 0/1 MEP to a protection group.
<east_sf_mep> : Mep_ID for finding out Continuity Check errors on Port 0.
<west_sf_mep> : Mep_ID for finding out Continuity Check errors on Port 1.
<east_raps_mep> : Mep_ID for transmitting R-APS frames on Port 0.
<west_raps_mep> : Mep_ID for transmitting R-APS frames on Port 1.
<group_id> : protection group id for which mep is associating.