Users Manual of SGSW-24040 / 24240 Series
340
<name>: System name or 'clear' to clear
System name is a text string drawn from the alphabet (A-Za-z), digits (0-9), minus sign (-). No blank or space characters
are permitted as part of a name. The first character must be an alpha character, and the first or last character must not be
a minus sign.
Example:
To set device title:
Switch/>System name SGSW-24040-LAB
System Contact
Description:
Set or show the system contact.
Syntax:
System Contact [<contact>]
Parameters:
<contact>: System contact string. Use 'clear' or "" to clear the string.
No blank or space characters are permitted as part of a contact. (only in CLI)
Default Setting:
empty
Example:
To set device contact:
Switch/>System contact SGSW-24040-Test
System Location
Description:
Set or show the system location.
Syntax:
System Location [<location>]
Parameters: