Example:
Set edge port BPDU filtering
SWITCH/>stp bpdufilter enable
STP BPDU Guard
Description:
Set or show edge port BPDU Guard.
Syntax:
STP bpduGuard [enable|disable]
Parameters:
enable|disable: enable or disable BPDU Guard for Edge ports
Default Setting:
Disable
Example:
Set edge port BPDU guard
SWITCH/>stp bpduguard enable
STP Recovery
Description:
Set or show edge port error recovery timeout.
Syntax:
STP recovery [<timeout>]
Parameters:
<timeout>: Time before error-disabled ports are reenabled (30-86400 seconds, 0 disables)
(default: Show recovery timeout)
Default Setting:
Disable