Displays current farm environmental conditions like temperature and humidity.
Shows ventilation step, type, air exchange, and set variations.
Displays graphical representations of ventilation and alarm set points.
Shows cooling and humidification temperature and humidity set points.
Displays flap settings for winter and summer modes, including pressure and temperature.
Shows heating temperature set points and output states for multiple heating units.
Displays average weight, weighing count, and uniformity of birds.
Shows distributed feed and water quantities, and feeding times.
Displays programmed and distributed meal quantities and silo status.
Shows current silo weight and silo uploading progress.
Procedure to silence the currently active alarm without affecting future alarms.
Procedure to reactivate a silenced alarm, allowing it to trigger again if needed.
Restarts the feeding/water system after an alarm stops it.
Displays the status of various alarms for climate, feeding, and other system parameters.
Sets parameters for heating, ventilation, and air exchange systems.
Sets meal times, light times, water times, and free timer settings.
Settings related to capture weight and the bird weighing process.
Allows creation and activation of curves for climate control based on days of life.
Procedure to start a new cycle, resetting previous data and enabling functions.
Configuration options for Heating, Flap, Ventilation, and Cooling systems.
Details on temperature set and conditionings for up to three heaters.
Configuration for flap control based on pressure, association, and natural modes.
Parameters for ventilation temperature set, air exchange, and 0-10V control.
Configuration for cooling set modes, temperature, humidity, and timing.
Settings for humidity start, temperature stop, and timing for humidification.
Configuration for CO2 and NH3 probe values at 4mA and 20mA.
Configuration for temperature, humidity, pressure, CO2, and NH3 alarms.
Configuration options for feed weighing, distribution, and lighting.
Settings for load cell data and plate calibration for bird weighing.
Configuration of minutes, hours, day of week, month, and year.
Option to select the desired language for the system interface.
Setting and managing user passwords for settings and installation access.
Settings for title bar, display brightness, minimum brightness, and waiting time.
Procedure for manually operating relay and 0-10V outputs for testing.
Parameters controlling the system's working mode, protected by password.
Resets all user-made settings back to the factory default configuration.
Setting the 485 node number for PC network communication.
Options for writing archives, settings, and uploading sets via USB pen drive.
Displays recorded alarms, failures, and events with timestamps.
Records daily indoor and outdoor climate conditions and working times.
Records daily feeding parameters, including distributed feed and water.
Records daily bird weighing data and average weight curves.
Records all silo loading events and quantities.
Displays total working times for ventilation, heating, and cooling systems.
Displays the state of ventilation, air exchange, heating, and flap blocks.
Shows average temperature calculations from selected probes.
Displays the operating status of flaps, including potentiometer feedback.
Displays the current state of various feeding-related alarms.
Summarizes the configuration of HXNE extension inputs for climate and feeding.
Summarizes the configuration of HDY6 extension output relays for various functions.
Summarizes the configuration of HXDA extension 0-10V outputs.
Checks the configuration of load cells for bird weighing and silo monitoring.
Identifies plant characteristics and system configuration settings.