8.7
ELECTRICAL
8
TRANSMISSION SWITCH
Transmission Switch - Circuit Breakout
Testing
1. With the switch installed, use an ohmmeter to test
continuity between the switch leads and engine ground.
2. First, shift the transmission into “neutral” and test for
continuity between the DG/WH wire and ground.
3. Then shift the transmission into “reverse” and test for
continuity between the DB wire and ground. In both tests
you should have continuity to ground.