Monthly Task Instruction
Drive Housing. out any debris. Be careful not to bring the vacuum cleaner
nozzle too close to any PCA circuit board which could be
damaged by ESD. It is recommended to use a vacuum
cleaner that is protected against electrostatic discharge).
Use rag to wipe and clean dust and dirt from components.
Verify the First and
Second Stage belt tension.
Verify the First and Second Stage belt tensions, see "First
Stage Drive Belt Tension Adjustment" on page32 and
."Second Stage Drive Tension Adjustment" on page36
Clean and lubricate the lift
motor jackscrew (Inline
models only).
Clean and lubricate the lift motor jackscrew with an
approved grease, see"General Information" on page3.
Inspect visible welds,
frame, and wire con-
nections
1
.
Do a visual check of welds and frame. Check for loose wire
connections.
Perform the Operation
Verification tests to verify
machine features and oper-
ation.
Do the Operation verification procedure and return to ser-
vice, see "Operation Verification" on page11.
Experience Series 800 Line EFX
144
8 Preventative Maintenance
Maintenance Schedule