Lift Motor Replacement
About
This procedure provides instruction to remove and install the Lift Motor.
Specifications
System Component Specification
Lift Motor Calibration Distance* 9 in
Yoke/Ramp Fasteners 320 in-lbs (236.2 Nm)
Note: * Calibration distance is set at incline level 10.
Lift motor power
Lift motor power is provided by the battery thru the lift motor fuse located on the LPCA
1
board,
see "LPCAFuse Locations" on page107.
Procedure
Review entire procedure before starting.
1
Lower PCA board
Experience Series 800 Line EFX
99
5 Replacement Procedures
Lift Motor Replacement