CONSOLE KEY FUNCTION/DESCRIPTION
PAUSE hardkey Stop a running diagnostic test.
Hardware Validation Service Menu (51765761)
Access Code: 5,1,7,6,5,7,6,1 (see "Service Access Codes" on pageî13)
The Hardware Validation menu provides a set of automated diagnostic tests and hardware cal-
ibration routines used to troubleshoot, calibrate, and verify machine operation. The diagnostic
tests are customized for the particular equipment type and console configuration.
P10, P20, and P30 consoles
Menu path:îHardware Validation Tests (5,1,7,6,5,7,6,1) > Hardware Validation Tests.
DIAGNOSTIC
TEST
TEST DESCRIPTION
DISPLAY TEST
Tests the console LEDs. Successively press the OK key to verify each
group of LEDs and verify that all LEDs illuminate. Press Back to exit the
test.
KEYBOARD TEST
An illuminated LED map of the function keys will be shown. Press each indi-
vidual key and verify that the corresponding LED extinguishes. Press and
hold BACK to exit the test.
PVS KEY TEST
Not used, OEM test.
HEART RATE
Tests the unfiltered, filtered, and pulse heart rate. Grasp the grips to test the
hand held heart rate. Use a Polar heart rate simulator to test the wireless
heart rate. Press the BACK button to exit this test.
Experience Series 800 Line EFX
18
3 Standard Service and Diagnostics Menus
Hardware Validation Service Menu (51765761)