S3.55 Assembly and Maintenance Guide
page 41
1 2 3 4 5 6
25. Attach the Cable to the Leg
Station
A. Press the Leg Extension Handle and move the
Rotating Arm up so that the base of the Leg
Station is easily accessible.
B. Feed the eye of Cable 46647-101 through the
Pulley Wing on the Leg Station.
Note: The Cable Eye will be connected to the
Rotating Arm.
C. Connect the Cable Eye to the Rotating Arm using
one clevis pin
two ¼-inch spacers
one E-clip
D. Press the Leg Extension Handle and lower the
Rotating Arm.
Step 25. Attach the Cable to the Leg Station
A
Rotating Arm
Leg Extension
Handle
Cable 46647-101
Pulley Wing
Leg
Station
1 - clevis pin
2 - ¼" spacers
1 - e-clip
Rotating Arm
C
B
D