11.3.2.1.2
‘Init’
Initial conditions
The triggering event
‘Init’
can be used to set initial conditions at
the beginning of a program sequence.
triggering event (trigger) Action
Init - Relay 2 closed
Init - Contact -
The example means:
As soon as the programme is started (via
‘Timer
è
Activation
è
active’
or power supply on),
‘Init’
sets
‘Relay 2’
to
‘closed’
and the
‘Operating mode’
to
‘Contact’
.
Example
11.3.2.1.3 Selecting cyclic time events and switching point
The cyclic time events periodically trigger actions. That is why a
program line consists of a cycle and a switching point:
The cycle specifies after which time the action is to be repeated.
The switching time specifies when the action is to take place.
Time events (triggers) Action
Cycle Switching time
Workdays 1 (Mo-Fr) Time of day 12:00 Manual
Example
Tab. 21: Cyclic time events
Cycle Time
‘hourly’
hourly at mm. Minute
‘daily’
daily at the time mm.ss, Monday to Sunday
‘Workdays 1 (Mo-Fr)’
daily at the time mm.ss, Monday to Friday
‘workdays 2 (Mo-Sa)’
daily at the time mm.ss, Monday to Saturday
‘Weekend (Sa+Su)’
daily at the time mm.ss, Saturday and Sunday
‘weekly’
weekly at the time mm.ss on day xxxxxx.
‘monthly’
monthly at the time mm.ss on the day dd. Day* of
the month
* Value range is restricted to day 01 – 28
CAUTION!
If you wish to use automatic summer time adjust‐
ment (
‘Settings’
-
‘Time’
) avoid in principle any
time events between 02:00 and 03:00.
Set up /
‘Menu’
83