RLX2 Series ♦802.11a, b, g, n Detailed Radio Configuration / Diagnostics
Industrial Hotspots User Manual
ProSoft Technology, Inc. Page 79 of 161
May 8, 2013
Field
Description
Delineation Method
None: All data received between packet delineation events is sent to
the remote node in a single network frame.
Time Gap: The minimum time gap between characters that is to be
interpreted as a delineator for a packet. Configure this value in the
EOL Time Gap field.
Character: The particular character sequence in the stream of
characters that indicates the delineator for the packet. Configure this
value in the EOL Delineator field.
EOL Delineator
Available when the selected Delineation Method is Character. Choose
the type of delineator to use from the dropdown list:
Available delineation types are:
Type
Decimal
Hex
Description
Use Text
Any string of characters
CR
13
0D
Carriage Return
ESC
27
1B
Escape
LF
10
0A
Line Feed (New Line / nl)
Null
00
00
Null
Spacebar
32
20
Space
Tab
09
09
Horizontal Tab
EOL Time Gap
Available when the selected Delineation Method is Time Gap; This
value configures the length of time in milliseconds that must elapse
after a character is received (from the local attached device) before
that character marks the end of a packet.
NOTE: the smallest value this field can be set to will be limited by the
device and is platform dependent.
Packet Rate
(milliseconds)
Sets the minimum time gap that will be interpreted as an inter-packet
space. When detected the characters received up to that point will
constitute a single packet and will be sent to the remote node. Units:
microseconds. Values: 1,000 to 500,000.
Baud Rate
Baud rate on the radio must match the baud rate on the connected
serial device.
Data Bits
Number of data bits (5, 6, 7 or 8). The data bits on the radio must
match the data bits on the connected serial device.
Parity
Parity (None, Even, Odd, 1 or 0). The parity on the radio must match
the parity on the connected serial device.
Flow Control
Flow control (handshaking) mode (None or Hardware). The
handshaking mode on the radio must match the handshaking mode on
the connected serial device.
Stop Bits
Stop bits (1 or 2). The stop bits on the radio must match the stop bits
on the connected serial device.
Save
Saves the changes and updates the radio configuration.
Cancel
Discards the changes without updating the radio configuration.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProSoft Technology RLX2-IHA and is the answer not in the manual?

ProSoft Technology RLX2-IHA Specifications

General IconGeneral
BrandProSoft Technology
ModelRLX2-IHA
CategoryWireless Router
LanguageEnglish

Related product manuals