EB200 Manual OUTPut subsystem
4052.2000.02 4.49 E-7
. . [:STATe]?
Query of squelch setting
Parameters:
none
Result:
1 squelch on
0 squelch off
State:
OUTPut:SQUelch? -> 1
. . :CONTrol MEMory|NONE
Selection of the source for the operating state after switching the unit on, when reading the memory
locations by the MEMory:COPY command, when using the RCL key or when running memory scan.
Parameters:
MEMory squelch state and squelch value are read out of the memory
locations
NONE squelch state and squelch value are not read out of the memory
locations
*RST state
MEMory
Example:
OUTPut:SQUelch:CONTrol NONE
. . :CONTrol?
Query of the source of squelch setting when reading memory locations
Parameters:
none
Result:
MEM, NONE
Example:
OUTPut : SQUelch : CONTrol?
→ MEM