EB200 Manual OUTPut subsystem
4052.2000.02 4.50 E-7
. . :THReshold
. . . [:UPPer] <numeric_value>|UP|DOWN|MINimum|MAXimum
Setting of squelch threshold
Parameters:
<numeric_value> squelch threshold in dBuV
UP|DOWN increase|decrease of squelch threshold by the value set with the
command OUTPut:SQUelch:THReshold[:UPPer]:
STEP[:INCRement].
MINimum|MAXimum setting the lowest/highest squelch threshold
*RST state:
10 dBuV
Example:
OUTPut:SQUelch:THReshold 35 dBuV
. . . ? [MINimum|MAXimum]
Query of squelch threshold
Parameters:
none query of current squelch threshold
MINimum|MAXimum query of lowest/highest squelch threshold
Result:
Level tone reference value in dBuV
Example:
OUTPut:SQUelch:THReshold? -> 35
. . . . :STEP
. . . . . [:INCRement] <numeric_value>|MINimum|MAXimum
Setting the stepwidth for the command OUTP:SQU:THR[:UPP] UP|DOWN
Parameters:
<numeric_value> stepwidth of squelch threshold in dBuV
MINimum|MAXimum setting the smallest|largest stepwidth
*RST state:
1 dBuV
Example:
OUTP:SQU:THR:STEP 10 dB
µV