Check the following functions of the electronic control unit:
Checking the forward speed sensor
Checking the filling level sensors
Metering shaft speed
Check the function of the sensors and actuators with the AERO ISOBUS electronic machine
control unit.
Observe the operator’s manual of the AERO ISOBUS electronic machine control unit.
n
Checking the metering shaft speed
u
Check
the gap size between the magnet
and the encoder [1].
There are a total of 6 encoders on the machine.
They are always placed directly on the metering
drive.
u
In case of faults, please follow the
instructions in chapter 9 Faults and
possible causes.
Fig. 68: Right metering
n
Checking the forward speed sensor
During transport and spreading, the current driving speed is displayed on the operating screen of the
machine control unit.
u
If this is not the case, check the driving speed sensor or the calibration.