Fig. 69: Operating screen
2 Display of current driving speed
The forward speed sensor is installed in the axle hub on the left in the direction of travel [3].
u
To check the installation position and the
sensor distance, remove the protective
sheet [4].
The distance between the wheel sensor
and the pulse wheel must be 3 mm.
u
Check the distance with a 3 mm thick metal
strip and adjust it, if necessary.
Fig. 70: Left wheel hub
n
Checking temperature sensor and cooler
Starting at an oil temperature of 62 °C, the oil cooler is switched on automatically. When the oil
temperature drops below 62 °C, the oil cooler is switched of