u
Press the OK button.
The new value is saved in the machine control unit.
The display switches to page 3.
The metering roller now fills the spreader tank and automatically stops after 15 s.
The display switches to page 4.
u
Empty the fertilizer collection tray and then place it back under the metering unit.
u
Press the OK button.
Page 5 appears.
u
Press the start/stop function key
.
u
The calibration procedure now runs automatically until metering switches off independently after
80 s.
u
The display switches to page 6.
u
Weigh the collected fertilizer quantity again.
u
Enter the collected fertilizer quantity.
The machine control uses the data to calculate the turns/kg.
u
Press the OK button.
The newly calculated turns/kg have been adopted.
You will return to the fertilizer settings menu.
The calibration test has been performed and is therefore complete.