CHAPTER 7
140 SmarTrax™ Calibration & Operation Manual
The hydraulic disengage switch or
transducer is not detected during
calibration.
The priority valve in the open
center valve is stuck.
Replace the cartridge.
Replace the open center valve.
Cable connection(s) to the
disengage switch is improperly
connected or loose.
Verify disengage switch
connections are correct and
secure.
The cable connection to the
transducer is improperly
connected or loose.
Verify the connection to the
transducer is correct and secure.
Problem Possible Cause Corrective Action