9
Manual No. 016-0171-122 Rev. I 175
Using AccuBoom™
AccuBoom™ Override Sec
The AccuBoom Override feature allows the operator to momentarily apply product to a previously applied area
while in a job. This feature is useful when backing into a corner during boundary spraying, to start product
application while the vehicle or implement is at a complete stop, or to apply additional product on a heavily
infested area of the field.
Enter the number of seconds for AccuBoom to apply product when the AccuBoom Override is selected.
Note: The Override Sec value is not used if a SwitchPro or CAN switch box is installed on the CANbus.
Enable Zero-Speed Override
Select this option to display the AccuBoom Override button automatically when the machine speed is zero.
Configuring AccuBoom™ Control
1. Touch the Booms area in the main Viper screen. The AccuBoom Control Setup screen displays.
2. Using the screen keyboard, enter a value, in seconds, in the ‘Turn-On’ Look-Ahead field.
3. Using the screen keyboard, enter a value, in seconds, in the ‘Turn-Off’ Look-Ahead field.
4. Using the screen keyboard, enter a value, in percentage, in the ‘Turn-Off’% Coverage field.
5. Using the screen keyboard, enter a value, if desired, in seconds, in the AccuBoom Override Sec field.
6. Select the ‘Enable Zero-Speed Override’ option to display the AccuBoom Override button automatically
when the machine is stopped.
Note: It is recommended to select the AccuBoom Override when accelerating from a complete stop to
allow the valves time to open and tips to develop a proper spray pattern.
7. Touch the Next button to setup the boom sections which AccuBoom may control automatically.