Chapter 9
176 Viper Pro Installation & Operation Manual
AccuBoom™ Boom Disable
The AccuBoom Boom Disable feature allows the operator to select which booms AccuBoom will automatically
control.
For example, if a machine has fence row nozzles that will be controlled manually, this feature allows the
operator to disable AccuBoom control of these booms.
Zero Rate Shut Off
Zero Rate Shut Off refers to products for which an Rx Map is used. If the target rate for an area is zero for all
Rx Maps, AccuBoom will shut off any controlled boom section that enters that area.
The Zero Rate Shutoff feature allows the operator to use AccuBoom to automatically turn off product control in
areas of an Rx map that has zero rate zones. This is particularly useful for spreader applications. By setting the
belt valve setting to PWM Close or Fast Close, AccuBoom will automatically turn off the belt when a zero rate
zone is entered. In addition, for a liquid machine, AccuBoom will automatically shut off any boom section that
has all Rx map products listing a zero rate zone.
Disabling Booms and Enabling Zero Rate Zone Shut Off
1. Touch the boom area on the main screen.
2. From the AccuBoom Control Setup screen, touch Next. The AccuBoom Control Setup screen displays.
3. Select the Enable option to allow AccuBoom control for selected boom sections or select the Disable
option to disable the AccuBoom feature.
4. Un-check boom sections which should not be controlled by the AccuBoom feature.
Note: AccuBoom will only control boom sections which have a check mark. Be sure that the same
sections enabled for AccuBoom Control are also selected on the Boom Select screen. See the
Section Assignments section on page 130 for information on selecting boom sections.
In a granular system with spinner control, disable the node associated with the spinner to allow the
spinner to run regardless of previous coverage or AccuBoom no-spray zones.
5. Check Enable Zero Rate Shut Off to enable this feature.
6. Touch the Next button to proceed to the AccuBoom Aggressiveness Factor screen.