4
Manual No. 016-0171-122 Rev. I 63
Initial Set Up and Navigation
CAN Controller Status
When configured to interface with a CAN network, the current control settings for each product node or control
channel are displayed on the CAN Controller Status screen.
The following information areas display on the CAN Controller Status screen:
The Boom Cals Area displays an overview of the current boom section widths and mapped display
characters. Review the Initial Set Up section on page 37 for details on configuring the boom or implement.
Refer to Section Assignments section on page 130 for more information on assigning products to specific
sections.
The Miscellaneous Settings Area displays an overview of current selections for the display units, speed
sensor and current vehicle speed, etc. Information about the CANbus nodes is also accessible by touching
within this area. Refer to the Miscellaneous Settings Area section on page 131 for more information.
Use the Node/Channel selection to view the current settings for a specific product node or control channel.
When modifying settings, be sure to select the appropriate product node or control channel before changing
any settings.
The Feature Settings Area displays an overview of the currently programmed alarm settings and features
for the selected product node or control channel. Refer to the Feature Settings Area section on page 134
for more information on available features accessible through the feature settings area.
The Product Control Settings Area displays the current calibration and application settings for the
selected product node or control channel. Refer to the Product Control Settings Area section on page 138
for more information on the settings required for controlling rate of product application.
The pressure registered by an optional transducer is displayed in the Pressures Area. Touch within the
pressures area to calibrate the pressure transducer. Refer to the Dual Pressure Area section on page 142
for more information.
The Application Area displays the selected application type and control valve selection for the selected
product node or control channel. Refer to the Application and Control Valve Type(s) section on page 40 for
more information on the control valve and application type settings.