6-6 Electrical Data Rexroth IndraDrive C
DOK-INDRV*-HCS02.1****-PR02-EN-P
Allowed DC Bus Continuous Power with Single-Phase Mains
Connection
For operation with single-phase mains supply, DC bus continuous powers
according to the diagrams below are allowed.
Note: Single-phase mains connection via the connections L1 and L2
is only allowed for single-source supply!
Apart from the specified continuous power, there is no peak
power available in the DC bus in the case of single-phase
operation.
0,0
0,2
0,4
0,6
0,8
1,0
1,2
1,4
1,6
1,8
200 250 300 350 400 450 500
U
LN
[V]
P
DC cont
[kW]
W0070
W0054
W0028
W0012
Fig. 6-5: P
DC_cont
HCS02.1E single-phase

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the REXROTH IndraDrive C Series and is the answer not in the manual?

REXROTH IndraDrive C Series Specifications

General IconGeneral
Protection ClassIP20
Communication InterfacesEtherCAT, PROFIBUS, PROFINET, CANopen
Feedback SystemsIncremental Encoders, Absolute Encoders, Resolver
Ambient Temperature0°C to 45°C
Cooling MethodNatural convection or forced air
Relative Humidity5% to 85% (non-condensing)
Control ModesTorque, position