SCANNER ACCESSIBILITY OPTION (B815)
B264/B265 1-84 SM
On-Site Installation
Move the Scanner Unit to Its Accessible Location
1. Disconnect the scanner unit from the
machine ( x3, x1)
2. Lift the scanner unit and set it at the
accessible location.
Replace the Cover
1. Remove the paper exit cover [A] ( x4)
2. Remove the upper right cover and
replace it with the cover [B] provided
with the Scanner Accessibility Option
B815 ( x1).
3. Attach the paper exit cover [C]
(provided with the option) ( x2).
Remove the Horizontal Arm
1. Remove:
[A]: Right cover( x1)
[B]: Left cover ( x2)
2. To remove the horizontal arm [C] of
the scanner stand, remove these
screws:
[D]: Top x2
[E]: Right side x6
[F]: Left side x6
B815I112.WMF
B815I113.WMF
B815I114.WMF
[A]
[A]
[C]
[D]
[E]
[F]
[A]
[B]
[C]