PHOTOCONDUCTOR UNIT (PCU)
SM 3-35 B264/B265
Replacement
Adjustment
3.11.5 DRUM CLEANING BLADE 2
1. Remove the OPC drum. ( 3.11.2)
2. Remove the charge roller and cleaning roller. ( 3.11.4)
3. Remove the movable cleaning blade [A]. ( x 1)
Re-installation
• Engage the left end of the cleaning blade first, then make sure that both arms [B]
and [C] are through the holes on the left and right side.
• When you re-attach the clip-ring, make sure that the head of the clip ring [D] is
below the blade.
CAUTION: After re-assembly make sure that the front spring of the movable
cleaning blade is re-attached to the , position. ( 3.11.2)
B195R939.WMF
[A]
[B]
[C]
[D]