B264/B265 6-100 SM
Fusing Idling Temperature
If copies are not sufficiently fused soon after the main power switch is turned on,
fusing idling should be enabled with SP1103 1.
When fusing idling is enabled, it is done when the temperature reaches the print
ready (“re-load”) temperature. The re-load temperature can be adjusted with
SP1105 5,6.
In the opposite case, even if fusing idling is disabled, it is done when the
temperature at power-up 15 °C
The fusing idling time is as follows.
Fusing Idling Mode Temperature at
power-on
0: Disabled 1: Enabled
SP1103 1
15 °C or less
30 s 30 s
Higher than 15°C
Not done 30 s
SP1103 2