DIP SWITCH SETTINGS
SM 17 B545
Two-Tray
Finisher
B545
3. SERVICE TABLES
3.1 DIP SWITCH SETTINGS
The DIP switches should not be set to any combination other than those described
in the table below.
DPS101
1 2 3 4
Mode Description
0 0 0 0 Default.
1 1 1 0 Free run. No paper.
0 0 0 1 Factory shipping. See the note below.
To position the shift trays for shipping, on the finisher main board set DIP SW4 ON,
cycle the main machine power off and on, then set DIP SW4 OFF. The
shift trays move automatically to the shipping position. After unpacking the
machine again and switching on, turn all DIP switches off to put the
machine into factory default mode.
3.2 TEST POINTS
No. Label Monitored Signal
TP101 GND Ground
TP102 5V 5V
TP103 RXD Received command data
TP104 TXD Transmitted command data
3.3 FUSES
No. Function
FU101 Protects 24 V.