IMAGE PROCESSING
B264/B265 6-34 SM
Text Mode
Adjust the image for the Text mode with the four master settings within their
allowed ranges (for ranges see Section “5. Service Tables”. To fine adjust a master
setting set it to “0” then perform the adjustments listed below.
SP4904 020 = 0 Text (General) Quality 25-64%
SP4903 020 Main Scan Filter Level: Text 25%-64%
SP4903 021 Sub Scan Filter Level: Text 25%-64%
SP4903 022 Main Scan Filter Strength: Text 25%-64%
SP4903 023 Sub Scan Filter Strength: Text 25%-64%
SP4904 021 = 0 Text (General) Quality 65-154%
SP4903 024 Main Scan Filter Level: Text 65%-154%
SP4903 025 Sub Scan Filter Level: Text 65%-154%
SP4903 026 Main Scan Filter Strength: Text 65%-154%
SP4903 027 Sub Scan Filter Strength: Text 65%-154%
SP4904 022 = 0 Text (General) Quality 155-256%
SP4903 028 Main Scan Filter Level: Text 155%-256%
SP4903 029 Sub Scan Filter Level: Text 155%-256%
SP4903 030 Main Scan Filter Strength: Text 155%-256%
SP4903 031 Sub Scan Filter Strength: Text 155%-256%
SP4904 023 = 0 Text (General) Quality 257%-400%
SP4903 032 Main Scan Filter Level: Text 257%-400%
SP4903 033 Sub Scan Filter Level: Text 257%-400%
SP4903 034 Main Scan Filter Strength: Text 257%-400%
SP4903 035 Sub Scan Filter Strength: Text 257%-400%