SERVICE PROGRAM MODE
SM 35 B779
Fax Option
B779
SP5-XXX (Initializing)
5
Mode No. Function
Initialize SRAM 101
000
Initializes the bit switches and user
parameters, user data in the SRAM, files in
the SAF memory, and clock.
Erase All Files 102
000 Erases all files stored in the SAF memory.
Reset Bit Switches 103
000
Resets the bit switches and user
parameters.
Factory setting 104
000
Resets the bit switches and user
parameters, user data in the SRAM and
files in the SAF memory.
Initialize All Bit Switches 105
000 Initializes all the current bit switch settings.
Initialize Security Bit Switches 106
000
Initializes only the security bit switches. If
you select automatic output/display for the
user parameter switches, the security
settings are initialized.
SP6-XXX (Reports)
6
Mode No. Function
System Parameter List 101
000
Touch the “ON” button to print the system
parameter list.
Service Monitor Report 102
000
Touch the “ON” button to print the service
monitor report.
G3 Protocol Dump List
001
G3 All
Communications
Prints the protocol dump list of all
communications for all G3 lines.
103
002
G3-1 (All
Communications)
Prints the protocol dump list of all
communications for the G3-1 line.
003
G3-1
(1 Communication)
Prints the protocol dump list of the last
communication for the G3-1 line.
004
G3-2
(All Communications)
Prints the protocol dump list of all
communications for the G3-2 line.
005
G3-2
(1 Communication)
Prints the protocol dump list of the last
communication for the G3-2 line.
006
G3-3
(All Communications)
Prints the protocol dump list of all
communications for the G3-3 line.
103
007
G3-3
(1 Communication)
Prints the protocol dump list of the last
communication for the G3-3 line.
G4 Protocol Dump List 104
001 Dch + Bch 1 Not used (Do not change the bit switches)