BIT SWITCHES
B779 40 SM
System Switch 02 SP No. 1-101-003
No FUNCTION COMMENTS
0 Not used Do not change these settings.
2 Force after transmission stall
0: Off
1: On
With this setting on, the machine resets itself
automatically if a transmission stalls and fails to
complete the job.
3 Not used Do not change these settings.
4
File retention time
0: Depends on User Parameter
24 [18(H)]
1: No limit
1: A file that had a communication error will not be
erased unless the communication is successful.
5 Not used Do not change this setting.
6-7
Memory read/write by RDS
Bit 7 6 Setting
0 0 Always disabled
0 1 User selectable
1 0 User selectable
1 1 Always enabled
(0,0): All RDS systems are always locked out.
(0,1), (1,0): Normally, RDS systems are locked out,
but the user can temporarily switch RDS on to allow
RDS operations to take place. RDS will
automatically be locked out again after a certain
time, which is stored in System Switch 03. Note that
if an RDS operation takes place, RDS will not switch
off until this time limit has expired.
(1,1): At any time, an RDS system can access the
machine.
System Switch 03 SP No. 1-101-004
No FUNCTION COMMENTS
0
to
7
Length of time that RDS is
temporarily switched on when
bits 6 and 7 of System Switch
02 are set to “User selectable”
00 - 99 hours (BCD).
This setting is only valid if bits 6 and 7 of System
Switch 02 are set to “User selectable”.
The default setting is 24 hours.
System Switch 04 SP No. 1-101-005
No FUNCTION COMMENTS
0-2 Not used Do not change these settings.
3
Printing dedicated tx
parameters on Quick/Speed
Dial Lists
0: Disabled
1: Enabled
1: Each Quick/Speed dial number on the list is
printed with the dedicated tx parameters (10 bytes
each).
The first 10 bytes of data are the programmed
dedicated tx parameters; 34 bytes of data are
printed (the other 24 bytes have no use for service
technicians).
4-7 Not used Do not change these settings.
System Switch 05 - Not used (Do not change the factory settings.)