BIT SWITCHES
SM 61 B779
Fax Option
B779
Communication Switch 02 SP No. 1-104-003
No FUNCTION COMMENTS
3
Hang-up decision when a
negative code (RTN or PIN) is
received during G3 immediate
transmission
0: No hang-up, 1: Hang-up
0: The next page will be sent even if RTN or PIN is
received.
1: The machine will send DCN and hang up if it
receives RTN or PIN.
This bit is ignored for memory transmissions or if
ECM is being used.
4-7 Not used Do not change the settings.
Communication Switch 03 SP No. 1-104-004
No FUNCTION COMMENTS
0
to
7
Maximum number of page
retransmissions in a G3
memory transmission
00 - FF (Hex) times.
This setting is not used if ECM is switched on.
Default setting - 03(H)
Communication Switch 04 - Not used (do not change the settings)
Communication Switch 05 - Not used (do not change the settings)
Communication Switch 06 - Not used (do not change the settings)
Communication Switch 07 - Not used (do not change the settings)
Communication Switch 08 - Not used (do not change the settings)
Communication Switch 09 - Not used (do not change the settings)
Communication Switch 0A SP No. 1-104-011
No FUNCTION COMMENTS
0
Point of resumption of memory
transmission upon redialing
0: From the error page
1: From page 1
0: The transmission begins from the page where
transmission failed the previous time.
1: Transmission begins from the first page, using
normal memory transmission.
1-7 Not used Do not change the settings.