BIT SWITCHES
B779 72 SM
G3 Switch 0A SP No. 1-105-011
No FUNCTION COMMENTS
6
Reconstruction time for the
first line in receive mode
0: 6 s 1: 12 s
When the sending terminal is controlled by a
computer, there may be a delay in receiving page
data after the local machine accepts set-up data and
sends CFR. This is outside the T.30
recommendation. But, if this delay occurs, set this
bit to 1 to give the sending machine more time to
send data.
Refer to error code 0-20.
ITU-T T.30 recommendation: The first line should
come within 5 s of CFR.
7 Not used Do not change the settings.
G3 Switch 0B Not used (do not change the settings).
G3 Switch 0C Not used (do not change the settings).
G3 Switch 0D Not used (do not change the settings).
G3 Switch 0E SP No 1-105-015
0-7 Set CNG send time interval
Some machines on the receiving side may not be able to automatically switch the 3-
second CNG interval.
High order bit 3000-2250ms: 3000-50xNms
3000 – 50 x Nms 0F (3000 ms) N FF (2250 ms)
Low order bit 00-0E(3000-3700ms: 3000+50xNms
3000 – 50 x Nms 0F (3000 ms) N 0F (3700 ms)
G3 Switch 0F SP No. 1-105-016
No FUNCTION COMMENTS
0
Alarm when an error occurred
in Phase C or later
0: Disabled
1: Enabled
If the customer wants to hear an alarm after each
error communication, change this bit to “1”.
1
Alarm when the handset is off-
hook at the end of
communication
0: Disabled
1: Enabled
If the customer wants to hear an alarm if the
handset is off-hook at the end of fax communication,
change this bit to “1”.
2-7 Not used Do not change the settings.