PRINTER ENGINE SERVICE MODE
G065 5-8 SM
SP1 Mode Number Function and [Setting]
04 Ends (By-pass)
[120°C ~ 220°C / 190°
°°
°C / 1°C step]
05 Center (Reload)
Adjusts the temperature for re-heating the center
of the hot roller:
Reload Temp. = Fusing. Temp – SP Value
[0°C ~ 60°C / 30°
°°
°C / 1°C step]
When the fusing temperature exceeds this
setting, the machine can operate.
Do not set a reload temperature (Spec. Temp –
SP Value) higher than the SP1105-02 setting.
06 Ends (Reload) Adjusts the temperature for re-heating the ends
of the hot roller:
Reload Temp. = Fusing. Temp – SP Value
[0°C ~ 60°C / 30°
°°
°C / 1°C step]
When the fusing temperature exceeds this
setting, the machine can operate.
Do not set a reload temperature (Spec. Temp –
SP Value) higher than the SP1105-02 setting.
07 Roller Center (By-pass)
Thick Paper
Adjusts the temperature of the center of the hot
roller for feeding thick paper with the by-pass
tray.
[120°C ~ 220°C / 200°
°°
°C / 1°C step]
08 Roller Ends (By-pass)
Thick Paper
Adjusts the temperature of the ends of the hot
roller for feeding thick paper with the by-pass
tray.
[120°C ~ 220°C / 200°
°°
°C / 1°C step]
09 Roller Center (Thick Paper) Adjusts the temperature for re-heating the center
of the hot roller for feeding thick paper:
Reload Temp. = Fusing. Temp – SP Value
[0°C ~ 60°
°°
°C / 5°
°°
°C / 1°C step]
When the fusing temperature exceeds this
setting, the machine can operate.
Do not set a reload temperature (Spec. Temp –
SP Value) higher than the SP1105-02 setting.
1105*
10 Roller Ends (Thick Paper) Adjusts the temperature for re-heating the ends
of the hot roller for feeding thick paper:
Reload Temp. = Fusing. Temp – SP Value
[0°C ~ 60°C / 5°
°°
°C / 1°C step]
When the fusing temperature exceeds this
setting, the machine can operate.
Do not set a reload temperature (Spec. Temp –
SP Value) higher than the SP1105-02 setting.
Temperature Display
Sets the temperature display to show the fusing temperature (monitored by
thermistors) for the center or ends of the hot roller, or the temperature of the I/O
Board at power on.
01 Roller Center
Monitors and displays temperature (°C) of the
hot roller center.
02 Roller Ends
Monitors and displays temperature (°C) of the
hot roller ends.
1106
03 I/O Temp.
Monitors and displays the temperature (°C) of
the I/O board at power on.