PM TABLES
SM 2-1 G065
Preventive
Maintenance
2. PREVENTIVE MAINTENANCE SCHEDULE
2.1 PM TABLES
2.1.1 PM TABLES FOR THE PRINTER
Two maintenance kits are provided for customers.
NAME CONTENTS
Maintenance Kit Type 4510A PCDU (Photo Conductor Cleaning/Development Unit)
Maintenance Kit Type 4510B Fusing Unit and Transfer Unit
Components marked with an asterisk (*) should be inspected, serviced, and
replaced without the maintenance kits.
NOTE: Amounts mentioned as the PM interval indicate the number of prints.
Symbol key: C: Clean, R: Replace, L: Lubricate, I: Inspect
EM 150K 300K 450K NOTE
PCDU
DRUM (OPC) AREA
Charge Roller* R R R
Cleaning Roller* R R R
Quenching Lamp C Dry cloth
Pick-off Pawls* R R R
Spurs C C C Dry cloth or alcohol
ID Sensor
CCC
Perform SP3001-02 after
blower brush cleaning.
CLEANING UNIT
Drum Cleaning Blade* R R R
Cleaning Entrance Seal
CCC
Blower brush, replace if
required.
Side Seal I I I
DEVELOPMENT
Development Drive Gears I I I Replace every 5 PM (750 K)
Development Filter* R R R
Developer* I R I
Entrance Seal I I I
Side Seal I I I
Development Roller C C C Dry cloth