1.SC Codes
318
Major Cause
ï‚· Master control board is defective.
ï‚· Connector loose, damaged, or defective.
Solution
ï‚· Reconnect the connector.
ï‚· Replace the relay board.
ï‚· Replace the master control board.
ï‚· Replace the harness.
SC750-13
Error Name
Perfect Binder: Slave-to-Cutter Control Board Communication Error 1
Pattern
D
Error Condition
Slave control board could not communicate with the cutter control board (communication alarm for over
5 sec.).
Major Cause
ï‚· Slave Control Board defective
ï‚· Cutter control board defective
ï‚· Connector loose, damaged, or defective.
Solution
ï‚· Reconnect the connector.
ï‚· Replace the slave control board.
ï‚· Replace the cutter control board.
ï‚· Replace the harness.
SC750-14
Error Name
Perfect Binder: Slave-to-Cutter Control Board Communication Error 2
Pattern
D