1.SC Codes
66
SC370-00
Error Name
ID Sensor Calibration Error
Pattern
D
Error Condition
This error is detected when the machine is unable to adjust the ID sensor (SEN92) output within the
prescribed range when performing process control.
The maximum value of the range is specified using SP3-320-013, and the minimum value of the range
is specified using SP3-320-014.
Major Cause
ï‚· The image transfer belt is wavy, or there is belt skew.
ï‚· ID sensor (SEN92) is defective.
Solution
1. Check if there is abnormality on the image transfer belt.
If so, repair or replace the image transfer belt, and then perform process control.
2. Replace the ID sensor (SEN92).
SC371-00
Error Name
ID Sensor Output Error: Background Area Output
Pattern
D
Error Condition
This error is detected when the ID sensor does not light up during the output check performed before ID
sensor calibration.
Major Cause
ï‚· ID sensor (SEN92) is not connected properly.
ï‚· ID sensor (SEN92) is defective.
ï‚· ID sensor (SEN92) harness is damaged.
Solution
1. Check whether the ID sensor (SEN92) is properly connected.