1.SC Codes
357
Solution
ï‚· Reconnect the connector.
ï‚· Replace the gluing unit.
ï‚· Replace the slave board.
SC750-85
Error Name
Perfect Binder: Glue Level Thermistor Disconnect Error
Pattern
D
Error Condition
ï‚· The AD value of the glue level thermistor was above 991 LSB for 10 sec.
ï‚· Temperature adjustment stops when the glue level sensor detects the temperature to be below 99
degrees for more than 10 sec.
ï‚· Other modes detected the error at the start of temperature adjustment. Temperature adjustment
stops and error detection is also stopped.
ï‚· There will not be error detection when temperature adjustment is stopped.
Major Cause
ï‚· Glue level thermistor defective
ï‚· Glue heater defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the gluing unit.
ï‚· Replace the slave board.
SC750-86
Error Name
Perfect Binder: Internal Temperature Thermostat Error
Pattern
D
Error Condition
The A/D value of the internal temperature thermostat was detected to be above 80 degrees for 1 sec.