1.SC Codes
508
SC754
SC754-10
Error Name
Perfect Binder: Signature Thickness Sensor Value Unstable Error
Pattern
B
Error Condition
The signature thickness reading did not change, even after the main grip unit opened and closed.
Major Cause
ï‚· Signature thickness sensor defective
ï‚· Connector loose, broken, defective
ï‚· Slave control board defective
ï‚· Master control board defective
ï‚· EEPROM on the master board defective
Solution
ï‚· Reconnect the connector.
ï‚· Specify the signature thickness again.
ï‚· Replace the signature thickness sensor.
ï‚· Replace the EEPROM on the master board.
ï‚· Replace the slave control board.
ï‚· Replace the master control board.
ï‚· Replace the sensor harness.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC754-11
Error Name
Perfect Binder: Glue Vat Roller Motor Error
Pattern
B
Error Condition
The glue vat roller rotation sensor could not detect rotation of the glue vat roller motor within 1200 ms of
motor operation.