1.SC Codes
466
Major Cause
ï‚· Book rotation motor 2 (left) connector, loose, broken, defective
ï‚· Motor overloaded, obstructed, defective
ï‚· Book rotation HP sensor 2 (left) connector loose, broken, defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the book rotation motor 2 (left).
ï‚· Replace the book rotation HP sensor 2 (left).
ï‚· Replace the cutter control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.
ï‚· Clear the signature jam.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC753-24
Error Name
Perfect Binder: Book rotation HP sensor (left) late error
Pattern
B
Error Condition
ï‚· The book rotation HP 2 (left) sensor did not go ON after the book was rotated 400 degrees.
ï‚· The book rotation HP 2 (left) sensor did not go ON after the book was rotated 400 degrees.
ï‚· Before the book is rotated before cutting, the book rotation HP sensor 2 (left) did not go on, even
after the book had been rotated twice the prescribed distance.
Major Cause
ï‚· Book rotation motor 2 (left) connector, loose, broken, defective
ï‚· Motor overloaded, obstructed, defective
ï‚· Book rotation HP sensor 2 (left) connector loose, broken, defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the book rotation motor 2 (left).
ï‚· Replace the book rotation HP sensor 2 (left).
ï‚· Replace the cutter control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.