EasyManua.ls Logo

Ricoh Pro 8310 - Belt Centering Sensor Error; Drum Cleaning Motor Error; Sc471-06; Sc480-00

Ricoh Pro 8310
963 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1.SC Codes
80
3. Remove ITB Unit, and check the steering control unit.
If a wire is disconnected, connect it again.
If mechanical parts are deformed, replace them.
4. Replace the electrical components.
ï‚· Belt centering motor (STM2)
ï‚· Belt centering roller HP sensor (SEN3)
ï‚· Belt centering sensor (SEN96)
5. Replace the ITB Unit.
SC471-06
Error Name
Belt Centering Sensor Error
Pattern
D
Error Condition
The output signal of Belt Centering Sensor is below the prescribed value.
Major Cause
ï‚· Image transfer belt is not in the correct position.
ï‚· When SC 471-04 or -05 occurred, the power is turned on/off by mistake and the belt position
shifted further than normal.
ï‚· Belt centering sensor (SEN96) is loose or disconnected.
ï‚· Belt centering sensor (SEN96) is defective.
Solution
1. Perform the procedure in ITB Centering: SC471-03, -04, -05, -06 (ITB Position Errors).
If the SC reoccurs go on to Steps 2 and 3.
2. Reconnect the belt centering sensor (SEN96).
3. Replace the belt centering sensor (SEN96).
SC480-00
Error Name
Drum Cleaning Motor Error
Pattern
D

Table of Contents

Other manuals for Ricoh Pro 8310

Related product manuals